Daily inspection and maintenance of enamel reactor

1, Listen to the enamel reactor reducer and motor sound is normal, start-up temperature of reducer, motor and bearing of machine base: general temperature ≤40°C, high temperature ≤60 °C (it is normal that the back of hand can stay on for more than 8 seconds) .

2, Often check the reducer oil leakage phenomenon, whether the shaft seal is intact, check the reducer oil level and oil quality changes, if necessary to add or update the corresponding oil.

3, Check the safety devices, such as safety valve, explosion-proof sheet, pressure gauge, thermometer and so on, if they are accurate, sensitive and easy to use, if the safety valve and pressure gauge have been checked, and the lead seal is intact, and if the Red Line of the pressure gauge is drawn correctly, whether the explosion-proof sheet is leaking inside.

4, Often listen to the enamel reactor is not abnormal vibration and sound.

Keep the shaft clean and exposed to light. Check that the shaft is rotating in a clockwise direction direction. Do not reverse the rotation.

6, Check the enamel reactor all import and export valve is intact. Check whether there are bolts loose, such as flange and machine base, safety shield is intact and reliable.

7, Check the reactor body has no cracks, deformation, bulging, perforation, corrosion, leakage and other phenomena, thermal insulation, paint is not complete, whether there is off, Scorch.